No. | Camera | Measuring part | Method used | Performance | References |
---|---|---|---|---|---|
1 | FLIROnePro | Head, back, back end | YOLOv3-SPP + Otsu | R2 = 0.774 | Küster et al. [ |
2 | Fluke TI32 | Head, ear | SVM | Acc: 0.97–0.98 | Lu et al. [ |
3 | MAG64AI | Ear | Semantic segmentation | Acc: 0.921 | Wang et al. [ |
4 | Fluke Ti-300 | Skin | BPNN, RF, SVR | MSE = 0.159°C | Jia et al. [ |
5 | Fotric 287-L20 | Body surface | Semantic segmentation and YOLOv4 | mAP = 94.20 | Xie et al. [ |
6 | Fluke Ti55 | Body surface | Fuzzy model | R2 = 0.95–0.99 | Oliveira et al. [ |
7 | FLIR T450sc | Back, head, ears | Regression models | Error= 1.5°C–1.7°C | Xiong et al. [ |
8 | Testo 876-1 | Body surface | Variance analysis | R2 = 0.81–0.82 | Caldara et al. [ |
9 | Flir ThermaCam | Body surface | Regression method | R2 = 0.38–0.80 | Tabuaciri et al. [ |
10 | Testo 876-1 | Skin | Decision tree | Acc: 0.91–0.99 | da Fonseca et al. [ |