Table 4. Outline of various studies on pig diseases and tracking using the IRT imaging technique

No. Camera Measuring part Method used Performance References
1 FLIROnePro Head, back, back end YOLOv3-SPP + Otsu R2 = 0.774 Küster et al. [77]
2 Fluke TI32 Head, ear SVM Acc: 0.97–0.98 Lu et al. [78]
3 MAG64AI Ear Semantic segmentation Acc: 0.921 Wang et al. [79]
4 Fluke Ti-300 Skin BPNN, RF, SVR MSE = 0.159°C Jia et al. [80]
5 Fotric 287-L20 Body surface Semantic segmentation and YOLOv4 mAP = 94.20 Xie et al. [81]
6 Fluke Ti55 Body surface Fuzzy model R2 = 0.95–0.99 Oliveira et al. [85]
7 FLIR T450sc Back, head, ears Regression models Error= 1.5°C–1.7°C Xiong et al. [82]
8 Testo 876-1 Body surface Variance analysis R2 = 0.81–0.82 Caldara et al. [83]
9 Flir ThermaCam Body surface Regression method R2 = 0.38–0.80 Tabuaciri et al. [86]