Sample integration time (SIT) |
NH3, CO2, and CH4 | Time required for measurement of all the gases at one SL- SIT5: 1 minute and 15 seconds- SIT20: 2 minutes and 30 seconds |
Number of repetitions |
NH3 | It is suggested to- Perform three repetitions in each SL; |
- Consider the mean value of the second and third repetitions as the estimated value of NH3 concentration determined at each SL; |
Sampling location (SL) |
Position | Central area of the barn |
Number | Two SLs reduced the variability of the concentrations below 15%.Three SLs reduced the variability of the concentrations below 10%. |
Distance between two SLs | A 10-meters distance between two SLs reduced data variability of NH3 concentration below 10% |