Research Article

Comparison of storage stability and palatability in different UHT milks during 9 mon at ambient temperature

Boin Lee1, Kyungchul Koh2, Young Min Choi1,*
Author Information & Copyright
1Sunmoon University, Asan 31460, Korea.
2KMRI, Gunpo 15871, Korea.
*Corresponding Author: Young Min Choi, Sunmoon University, Asan 31460, Korea, Republic of. E-mail: ymchoi11@sunmoon.ac.kr.

© Copyright 2026 Korean Society of Animal Science and Technology. This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Received: Oct 14, 2025; Revised: Dec 05, 2025; Accepted: Apr 27, 2026

Published Online: May 27, 2026

Abstract

This study evaluated the storage stability and palatability of imported ultra-high temperature (UHT) milks during prolonged ambient storage (4–9 mon), compared with domestic high temperature short time (HTST) milk stored under refrigeration for 1 wk. HTST milk, produced within 7 d, was purchased from a local market and stored under refrigeration as a control. UHT milks produced 3 mon prior from Australia (UHT-A), Germany (UHT-G), and Poland (UHT-P) were stored at 25 ± 2℃ in a temperature-controlled incubator. All milks had a comparable amount of total solids, with fat (3.4–3.5 g/100 g), protein (3.0–3.3 g/100 g), and carbohydrate (4.7–5.0 g/100 g) contents. UHT milks consistently exhibited higher thiobarbituric acid reactive substances values than HTST milk throughout storage (p < 0.05), although all values remained below the safety threshold for consumption. Protein degradation was observed in all UHT milks during storage (p < 0.05), except for αs-casein (p > 0.05). β-casein gradually decreased in UHT-A and UHT-G from 4 to 9 mon (p < 0.001), while κ-casein decreased in UHT-A and UHT-P over the same period (p < 0.001). Sensory evaluation by trained panelists showed that HTST milk had a stronger milky flavor than all UHT milks, regardless of the storage period (p < 0.001). In contrast, all UHT milks had greater cooked and cheesy flavors than HTST milk (p < 0.001), likely due to exposure to higher temperatures. Rancid aromatic flavor increased during storage in UHT-A and UHT-P milks (p < 0.001). In addition, all UHT milks showed higher viscosity and astringency scores than HTST milk throughout storage (p < 0.001). Overall, prolonged ambient storage of imported UHT milk induced persistent physicochemical changes, including lipid oxidation and protein degradation, ultimately leading to a gradual decline in palatability, a critical determinant of consumer acceptability.

Keywords: Ultra-high temperature milk; Storage stability; Lipid oxidation; Protein degradation; Sensory quality


Revised Publication Charge


(Effective for articles submitted beginning January 1, 2026)

The publication charge is 1,500,000 Korean Won per article for members of the Korean Society of Animal Science and Technology (KSAST), and 2,000,000 Korean Won for non-members. First and corresponding authors are required to pay the annual membership fee.

The publication charge for a corresponding author outside Korea is 1,500 US dollars per article.


I don't want to open this window for a day.