Research Article

A TMAH-Chloroform Sample-Preparation Workflow for Nile Red-Based Screening of Microplastics in Animal Feed

Veysel Doğan 1 , *
Author Information & Copyright ▼
1Department of Animal Nutrition and Nutritional Diseases, Faculty of Veterinary Medicine, Kastamonu University, Kastamonu 37200, Turkey.
*Corresponding Author: Veysel Doğan, Department of Animal Nutrition and Nutritional Diseases, Faculty of Veterinary Medicine, Kastamonu University, Kastamonu 37200, Turkey. Phone: +90-366-280-6029. E-mail: d_veysel@yahoo.com.

© Copyright 2026 Korean Society of Animal Science and Technology. This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Received: Jul 07, 2026; Revised: Sep 15, 2026; Accepted: Oct 08, 2026

Published Online: Nov 13, 2026

Abstract

Animal feed is increasingly recognized as an important route of microplastic (MP) exposure in livestock production systems; however, reliable fluorescence-based detection remains challenging because proteins, lipids, pigments, and other organic constituents interfere with fluorescence analyses. This study developed and evaluated a sample-preparation protocol combining tetramethylammonium hydroxide (TMAH) digestion with chloroform (TCM) extraction to reduce matrix interference while preserving the fluorescence characteristics of MP particles prior to Nile Red (NR) staining. The protocol was evaluated using five commercially available animal feeds (layer, broiler, calf starter, calf grower, and turkey feeds) and four representative polymers: polyethylene (PE), polypropylene (PP), polystyrene (PS), and polyethylene terephthalate (PET). Fluorescence microscopy, quantitative fluorescence intensity measurement, linear regression analysis, and discriminant function analysis were used to assess the analytical performance of the proposed workflow. The evaluated protocol reduced matrix-derived fluorescence interference and enabled clear visualization of NR-positive particles without significantly altering the fluorescence responses of the reference polymers. Among the tested polymers, PS exhibited the highest fluorescence intensity (174.69 ± 20.91), followed by PP (143.21 ± 37.74), PE (134.03 ± 38.36), and PET (117.59 ± 36.93). Significant differences in fluorescence intensity were observed among polymer types (p < 0.05), and discriminant function analysis demonstrated that fluorescence intensity can serve as a complementary analytical parameter for polymer differentiation, although classification accuracy remained moderate (47%). Collectively, the proposed TMAH-TCM workflow provides a practical sample-preparation approach for NR-based screening of MP in animal feed matrices, while fluorescence intensity may provide complementary information for preliminary polymer differentiation. 

Keywords: Microplastics; Animal Feed; Fluorescence Microscopy; Nile Red; One Health; Nutrition


Revised Publication Charge


(Effective for articles submitted beginning January 1, 2026)

The publication charge is 1,500,000 Korean Won per article for members of the Korean Society of Animal Science and Technology (KSAST), and 2,000,000 Korean Won for non-members. First and corresponding authors are required to pay the annual membership fee.

The publication charge for a corresponding author outside Korea is 1,500 US dollars per article.


I don't want to open this window for a week.