Article

Exosomes isolation from bovine serum: Qualitative and quantitative comparison between ultracentrifugation, combination ultracentrifugation and size exclusion chromatography, and exoEasy methods

Eun-Yeong Bok1, Sang Yeong Seo1, Han Gyu Lee1, Eun Ju Kim1, Ara Cho1, Young-Hun Jung1, Tai-Young Hur1, Kyoung-Min So1, Sung-Lim Lee2,3, Sudu Hakuruge Wimalasena1, Yoon Jung Do1,*
Author Information & Copyright
1Division of Animal Diseases & Health, National institute of animal science, Rural Development Administration, wanju 55365, Korea.
2College of Veterinary Medicine, Gyeongsang National University, Jinju 52828, Korea.
3Research Institute of Life Science, Gyeongsang National University, Jinju 52828, Korea.
*Corresponding Author: Yoon Jung Do, Division of Animal Diseases & Health, National institute of animal science, Rural Development Administration, wanju 55365, Korea. E-mail: clonea@korea.kr.

© Copyright 2024 Korean Society of Animal Science and Technology. This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Exosomes have been extensively studied as disease biomarker in humans, given their role in transporting bioactive molecules. However, despite the great potential of exosomes as noninvasive diagnostic markers and therapeutic nanocarriers for bovine diseases, few studies have been conducted on bovine exosome.  Thus, this study aimed to quantitatively and qualitatively compare three isolation methods to identify a suitable method for bovine serum. Exosomes were isolated using ultracentrifugation alone (UC), a combination of ultracentrifugation and size exclusion chromatography (US), or membrane affinity-based exoEasy kit (EE). Isolated particles were evaluated using a range of complementary techniques. Transmission electron microscopy showed that all three isolation methods resulted in particles with a cup-shaped morphology. The particle concentration measured by nanoparticle trafficking analyzer of US was lower compared to those of UC and EE method. As a result of immunoblotting, exosome markers including TSG101, CD81, and HSP70 were detected in US particles, while in UC and EE, only TSG101 expression was confirmed. Particles isolated from UC and EE showed a contamination with the blood protein albumin, whereas particles from US did not show albumin contamination. In addition, to evaluate the possibility of using exosomes as biomarkers, the profiles of the small RNA in the exosomes were compared using the bioanalyzer 2100. As a result, in the EE method, the band of small RNA (25-200 nt) was most prominent, and in the US methods, a distinct band was observed in the small RNA range. Collectively, the purity of exosomes without non-exosomal contamination was highest in the US method. However, for the detection of small RNA, the EE method was found to be the most suitable. Therefore, the results suggest that the optimal isolation method varies depending on the specific purpose of exosome isolation.

Keywords: Exosomes; Ultracentrifugation; Combination of ultracentrifugation and size-exclusion chromatography; exoEasy kit; Bovine serum